Thank you for choosing an Aquamor® UF System Controller. Designed and assembled in the USA, the controller is the command center of your Ultrafiltration (UF) System. It runs the flush valve on a schedule you set, so your UF membrane stays clean with no daily effort from you.

The controller is a low-voltage electronic timer. It connects to a power adapter and to one or two flush ball valves. On the schedule you program, it opens each valve for a set time to flush the membrane, then closes it again.

This manual covers the controller only. It walks you through four tasks, in order:

  1. Connect the power adapter.
  2. Connect the flush ball valve (or two valves on a two-stage system).
  3. Program the flush schedule.
  4. Run a manual flush.

The first three connection steps are done once, at install. Programming and manual flushing are things you can do any time. Each step is labeled so you know whether it is an install task or an everyday task. Please read this manual completely before installing or operating the controller, and retain it for future reference.

Technical Assistance

If you have any problems with the installation or operation of your UF System Controller, please contact Aquamor Customer Service. Customer Service is open Monday through Friday, 8 am to 5 pm Pacific.

AQUAMOR, LLC
42188 Rio Nedo
Temecula, CA 92590 U.S.A.
Customer Service, Mon–Fri 8 am–5 pm Pacific
(951) 541-9517
customerservice@aquamor.com

Table of Contents

Owner Information
General
Technical Assistance
Important Safety Information
Controller Specifications
Installation
The Controller and Its Ports
Power Supply Connection
Flush Valve Connection
Replacement Parts
Programming
Entering Programming Mode
Start Time · Flush Duration
Flush Interval · RTC Time
24-Hour Time Reference
Operation
Manual Flush
Troubleshooting
Warranty and Support
Limited Warranty
No Routine Maintenance
Contact Aquamor Customer Service
IMPORTANT SAFETY INFORMATION

Read all instructions before use. Save these instructions. The UF Controller runs on household power and is installed next to plumbing. Read these safety messages before you connect or operate it. They appear again, in shorter form, at the exact step where each hazard applies.

WARNING

Electric shock. Mains voltage is present at the power adapter and its cord. Contact can cause serious injury or death. Connect the adapter only to a properly grounded outlet. Do not use a damaged cord or plug.

WARNING

Water and electricity. This controller is used near plumbing. If the adapter, cord, or plug touches water, you can get a shock. Keep the adapter, cord, and plug dry and off the floor. Do not immerse them. Mount the controller above any place water could spray or pool.

WARNING

Ground-fault protection. A ground fault near water can cause electric shock. Aquamor recommends plugging the adapter into a GFCI-protected outlet and testing the GFCI per its instructions.

CAUTION

Cord routing. A cord run near hot surfaces or pinch points can be damaged, leading to shock or fire. Route the cord away from hot surfaces and sharp edges. Do not pinch it under the bracket or in a cabinet door.

CONTROLLER SPECIFICATIONS
ItemRating
Electrical input120 VAC, 0.4 A
Electrical output24 V DC
Controller part number503041 (pulse controller, with LCD, UF)
Flush ball valve part number503043 (3/4 NPT stainless steel, with harness)
Power adapter part number503033 (universal)
Controller dimensions (overall)6.5 in L x 3.85 in W x 1.36 in D
Mounting holes0.18 in diameter, 6 in apart
Controller weight0.472 lbs
Operating temperature32-104 F (0-40 C)
Enclosure protectionIndoor use, not IP-rated
Flush ball valve electrical rating (P/N 503043)9-24 V AC/DC, IP65, max power 5 W
INSTALLATION
For the Installer

The Controller and Its Ports

The Aquamor UF Controller works with both a single-stage UF System and a two-stage UF System. The controller has six ports. Three of them are used during a normal install:

  1. Power port (far left)
  2. UF #1 flush ball valve port
  3. UF #2 flush ball valve port (two-stage systems)
UF Controller showing the row of six ports 1 2 3
1 Power Port 2 UF #1 Port 3 UF #2 Port
Figure 1. The Controller Ports
The three labeled ports are the ones you connect: power (1), UF #1 (2), and UF #2 (3). The unlabeled ports between them are reserved for a future pressure connection and for programming. Do not connect anything to those.
NOTICE

Connect the power supply to Port 1, the far-left port, and nowhere else. Ports 2 and 3, the two ports just to the right of the power port, have the same two-hole size and shape as the power port but are not power inputs. They are reserved for a future pressure connection.

Applying power to Port 2 or Port 3 will burn out the control board and permanently destroy the controller. Before plugging in, confirm the power harness is seated in the far-left port.

Power Supply Connection

WARNING

Electric shock. Mains voltage is present at the power adapter and cord. Contact can cause serious injury or death. Keep the adapter unplugged from the wall outlet until every connection in this Installation section is made.

Water and electricity. Keep the adapter, cord, and plug dry and off the floor. Do not immerse them. Mount the controller above any place water could spray or pool.

Take the included power supply with harness, and with the tab facing up as shown, insert the plug into the left-most port of the controller.

Power supply harness plugged into the leftmost port
Figure 2. Power Supply Harness Seated in the Left-Most Port, Locking Tab Up

Flush Valve Connection

Take the flush ball valve with harness, and with the locking tab facing up as shown, insert the harness into the UF #1 Port.

Note: There are a total of six ports on the Controller. Port 1 (far left) is power. Ports 2 and 3 are reserved for a future pressure connection and share the same two-hole configuration as the power port. Port 4 is the programming port. The valve ports are last: UF #1 is the fifth port from the left and UF #2 is the sixth.
Flush ball-valve harness with locking tab inserted Locking tab, facing up
Figure 3. Insert the Harness with the Locking Tab Facing Up

Your controller should look like this when the power and UF #1 port have been properly installed.

Controller with power and UF #1 connected, UF #2 port open UF #2 Port (2-stage systems)
Figure 4. Power Supply (Left) and UF #1 (Port 5) Connected; UF #2 Port Remains Open
Note: If you have a two-stage UF System, connect the UF #2 Port (to the right of the #1 Port) to the second flush ball valve.
PROGRAMMING
For the User

Entering Programming Mode

WARNING

Electric shock. You are about to connect to mains power. Use a properly grounded outlet. Do not use a damaged cord or plug. Aquamor recommends a GFCI-protected outlet; test the GFCI per its instructions.

Cord routing. Route the cord away from hot surfaces and sharp edges. Do not pinch it under the bracket or in a cabinet door.

To enter programming mode:

  1. Plug the controller into a power outlet.
  2. Push the Right Arrow Button once.

The screen enters programming mode, as shown below.

Two thumbs pressing buttons in programming mode
Figure 5. The Controller in Programming Mode

Start Time

Set the start time of day for the UF to flush.

Note: The Aquamor UF Controller uses the 24-hour clock (24-hour time) only.

The first line to program is the Start Time: when the first flush takes place in a 24-hour period. Press the "Right Arrow Button" to align the cursor under the digit you want to change, then use the up/down arrows to change it. Below, the first flush is set for 3:00 am.

UF Controller
Start Time:03:00
Flush
Duration:15 seconds
Flush
Interval:24 hours
RTC Time:03:00
Screen A: Start Time Highlighted, Set to 03:00 (3:00 am)

Flush Duration

Flush duration is how long the flush ball valve stays open during a flush. Press the Right Arrow Button again to move the cursor to Flush Duration. Duration is set in 5-second steps, from 5 to 60 seconds. The default is 15 seconds. On a 15-second flush at 60 PSI water pressure, the valve will flush 4 gallons of water.

UF Controller
Start Time:03:00
Flush
Duration:15 seconds
Flush
Interval:24 hours
RTC Time:03:00
Screen B: Flush Duration Highlighted, Set to 15 Seconds (Default)

Flush Interval

Flush Interval sets how many times the UF Membrane flushes within a 24-hour period:

Interval (Hours)Flush Frequency
24One flush daily
12Every 12 hours: twice daily
6Every 6 hours: 4 flushes daily
4Every 4 hours: 6 flushes daily
2Every 2 hours: 12 flushes daily
1Every hour: 24 flushes daily

We also offer 45-, 30-, and 15-minute options for excessively dirty water. Press the "Right Arrow Button" until the cursor is under Flush Interval, then use the up/down arrows to adjust.

UF Controller
Start Time:03:00
Flush
Duration:15 seconds
Flush
Interval:24 hours
RTC Time:03:00
Screen C: Flush Interval Highlighted, Set to 24 Hours (One Flush Daily)

RTC Time

Note: The Aquamor UF Controller uses the 24-hour clock (24-hour time) only.

Once the Flush Interval is set, set the current time on the Real Time Clock (RTC):

  1. Push the Right Arrow Button to move to the RTC Time setting.
  2. Set the digit under the cursor with the up and down arrows.
  3. Push the Right Arrow Button to move to the next digit.
  4. Repeat until all four time digits are set.
UF Controller
Start Time:03:00
Flush
Duration:15 seconds
Flush
Interval:24 hours
RTC Time:03:00
Screen D: RTC Time Highlighted

For Reference: 24-Hour Time Conversion

Normal24-HourNormal24-Hour
12:00 AM000012:00 PM1200
1:00 AM01001:00 PM1300
2:00 AM02002:00 PM1400
3:00 AM03003:00 PM1500
4:00 AM04004:00 PM1600
5:00 AM05005:00 PM1700
6:00 AM06006:00 PM1800
7:00 AM07007:00 PM1900
8:00 AM08008:00 PM2000
9:00 AM09009:00 PM2100
10:00 AM100010:00 PM2200
11:00 AM110011:00 PM2300
OPERATION
For the User

Manual Flush

You can start a manual flush any time, apart from the programmed flush times. Press and hold the left and right arrows together for 5 seconds. The screen switches from the time-of-day display to the programming screen. When the flush finishes, the screen returns to the time-of-day display on its own.

Controller front face for the manual flush step Press and hold 5 sec
Figure 6. Press and Hold the LEFT and RIGHT Arrows Together for 5 Seconds
TROUBLESHOOTING

If the controller does not behave as expected, find the symptom below and try the action. When a row says to disconnect power and contact Customer Service, stop and do that before going further.

SymptomLikely CauseWhat to Do
Blank or dark screen No power. Adapter not seated in the power port, outlet is dead, or adapter has failed. Confirm the adapter is seated in Port 1 (far left). Try a known-good outlet. If the screen is still blank, disconnect power and contact Customer Service.
Will not flush or valve does not actuate Valve harness in the wrong port or unseated, flush interval or duration set wrong, or a valve fault. Confirm the valve harness is seated in the UF #1 Port. Check the flush interval and duration. Run a manual flush (see Operation). If it still does not flush, disconnect power and contact Customer Service.
Settings do not save or do not survive a power cycle Programming was not committed, or a clock or backup fault. Re-enter the settings and confirm each value on the screen. If the settings still reset after a power cycle, disconnect power and contact Customer Service.
Flushing too often or not at all Flush interval set wrong, or the start time and clock time do not match. Check the Flush Interval and confirm the RTC Time matches the current time of day (see Programming).
Water at a port, or moisture on the controller A leak or spray has reached the controller. Shock hazard. Stop. Disconnect power at the outlet. Do not touch the controller until it is dry. Contact Customer Service.
REPLACEMENT PARTS

Order replacement components by part number. To order, contact Aquamor Customer Service at (951) 541-9517.

Part NumberDescription
503041UF System Controller: pulse controller, with LCD, UF
503043Flush ball valve: 3/4 NPT stainless steel, with harness
503033Power adapter: universal; input 120 VAC, 0.4 A; output 24 V DC
WARRANTY AND SUPPORT

Limited Warranty

Aquamor, LLC warrants the UF System Controller to be free from defects in materials and workmanship for a period of one (1) year from the date of shipment, subject to proper installation, operation within the ratings stated in Controller Specifications, and use for its intended purpose. This warranty does not cover damage from improper installation, misuse, or operation outside the ratings and conditions described in this manual.

For the full coverage terms, exclusions, and claim procedure, see the Limited Product Warranty at aquamor.com/warranty-returns or contact Aquamor Customer Service to start a claim.

No Routine Maintenance

Beyond the programming steps in this manual, the controller requires no routine maintenance. If it is not operating as expected, see Troubleshooting or contact Aquamor Customer Service.

Contact Aquamor Customer Service

AQUAMOR, LLC
42188 Rio Nedo
Temecula, CA 92590 U.S.A.
Toll-free: 1-866-218-8473
Direct / international: 951-541-9517
customerservice@aquamor.com
Aquamor
Thank You

Thank you for choosing Aquamor. Your UF Controller is set up to keep your UF membrane clean on the schedule you chose. If you ever need to change the schedule or run a manual flush, the steps in this manual will walk you through it. Our Customer Service team is here if you have questions.

Clean Water. Clear Dedication.
AQUAMOR, LLC
42188 Rio Nedo
Temecula, CA 92590 U.S.A.
Customer Service, Mon–Fri 8 am–5 pm Pacific
(951) 541-9517
customerservice@aquamor.com
Designed and Assembled in the USA
Back to top
Aquamor facility at sunset
AQUAMOR, LLC
42188 Rio Nedo, Temecula, CA 92590 U.S.A.
UF System Controller User Manual
Rev. 2026-07